<Error>
<ErrorNumber>15224</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: picker microswitch activated before plate seek, check switch,
cable and plate_jog_y
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Resume if possible.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Before the picker moves in to sense the depth of the plate stack, it checks
that the picker microswitch is not already activated, if it is then
this error is generated.
</text></DescriptionText>
</ServiceInformation>
<Cause>
This could be caused by a faulty picker microswithc or cable.  There are
two picker microswitches behind the outer two sucction cups that sense when the
cup spring is compressed. They are connected in parallel and are closed when
the cup is NOT compressed, therefore if this error is reported, either the
wire from the picker transition board to the first micro switch is faulty or
both picker microswitches are open circuit.
</Cause>
<Cause>
This is only reported if the pms is enabled.
</Cause>
<Cause>
This will prevent the py axis moving towards the plate stack.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_npm.xml</LinkAddress><LinkTitle>NVS: al npm</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>